Tuesday, February 9, 2016

Product Highlight- MiSeal Thermal Vessel Sealing System


Have you heard of the 
MiSeal Thermal Vessel Sealing System?


The MiSeal Thermal Ligating System offers surgical instruments used to seal and divide tissue utilizing proprietary Thermal Fusion Technology. 

The MiSeal consists of three different parts:

Reusable 5mm Handpiece


The reusable hand-piece offers cost-effective, eco-friendly benefits compared to fully disposable devices. This hand-piece boasts a 360 degree shaft rotation, a 5 mm diameter insertion shaft, and is available in 14 cm and 35 cm lengths. 

Thermal Ligating Shears Kit


This tip utilizes proprietary Thermal Fusion technology to facilitate the precise application of heat, which minimizes collateral damage. The tip has a curved Maryland-style jaw with an active length of 16.4 mm. The instrument cord is approximately 3 meters long and connects the hand-piece to the Universal Power Supply. 
(Each kit includes five (5) tips and an active cord)

Universal Power Supply


Universal Power Supply converts AC power from a hospital-grade wall outlet into low voltage DC power required by all MiFusion instruments. The UPS is compatible with voltages worldwide. In addition, the UPS is a compact, 3-lb unit that can easily be suspended from an I.V pole or placed on any flat surface, making the UPS portable and easy to use. 


Want to know more about the MiSeal Thermal
 Vessel Sealing System? 

Check out our online store or contact us!

Make sure to visit us next week for another
ESS Product Highlight!

Monday, February 8, 2016

Happy Chinese New Year!


Have a good year of the Monkey!

Laparoscopy


Laparoscopy in a canine patient performed by
 a travelling vet in Pennsylvania .
 USB Camera was used alongside
 normal laparascopic tools. 


To learn more about our USB Camera or
 other Laparascopic tools,
 check out our online store!

Sunday, February 7, 2016

Superbowl!


Today's the day of the big game!
Who will you be rooting for? 



Friday, February 5, 2016

Did You Know?

Did you know that ESS sells
 used/refurbished equipment? 



Check out our online store to see
 which product fits your needs!

Thursday, February 4, 2016

Cystoscopy


Performing a Cystoscopy in a canine patient. 

If you want to learn more about the products used in this Cystoscopy, check out our online store or contact us!

Wednesday, February 3, 2016

Helpful Hints and Information: Part 2- Common handling errors

Common Handling Errors.




1- Delaying repairs. 
Worsens the scopes conditions. 

2- Not properly following disinfectant manufacturer's instructions and immersing scope in disinfectant too long or at improper concentrations. 
This can cause corrosion and premature wear. 

3- Immersion in fluid with the vent cap on. 
The vent is the "door" to your scope, and if left on, it allows fluid invasion. 

4- Delaying initial cleaning. 
This contributes to corrosion and premature wear. 

5- Reprocessing with other instruments.

6- Transporting and gas sterilizing without the vent cap attached. 

7- Storing in carrying case or communal storage. 
Doing this compromises sterility and proper ventilation.
The Scopes should be completely dry before storing and should be
 kept in a dry, well-ventilated environment. 

8- Not verifying compatibility of light source to scope. 

9- Manually articulating scope. 
You should only use the lever control. 

10- Third party repairs. 

11- Stretching/folding of sheathing or cover. 



Remember!

Proper maintenance and handling of your endoscopes will
 increase the life of the unit, lower repair or replacement costs,
 and reduce the possibility of cross-contamination. (to patients and other instruments.)


Tuesday, February 2, 2016

Product Highlight-'The Ratigator' Combo Retriever


Have you heard about 
The Ratigator? 




This special, reusable grasper combines both the rat tooth and alligator jaw grasping jaws creating a product that is the best of both worlds: the flat, gripping power of an alligator jaw and the precision 'pinch-hook' ability of the rat tooth!

The Ratigator is reusable, repairable, autoclavable, and features an ergonomic plunger-style plastic handle. 



It comes in two different sizes:
1.8mm x 190cm, 8mm Jaw Opening
or
2.4mm x 230cm, 15mm Jaw Opening


Want to see The Ratigator in action? 
Check out these previous posts!


If you think that The Ratigator is right for you
 or you want to know more information, 
check out our online store or contact us!

Make sure to come by next week for another
 ESS Product Highlight!

Groundhog Day


Happy Groundhog Day! 
Let's hope he doesn't see his shadow and we get an early spring!
(Also, that none of you have to repeat this day
 over and over and over...)

Monday, February 1, 2016

Laparoscopy


Laparoscopy performed using our USB Camera and
the MiSeal Device. 

For more information about either
 of these products, check out our 
online store or contact us directly!




Thursday, January 28, 2016

Endoscopy in Cats and Dogs

Are you concerned if your furry friend needs to go for some endoscopic procedure? 



Don't be!

Our friends over at VCA Animal Hospitals have
 put together these two articles about 
to explain what exactly is to be expected.  

Tuesday, January 26, 2016

Laparoscopy Procedure


Sales manager Rich instructing
 in a Laparoscopy Procedure.

Broken Scope?

Dealing with a broken or damaged scope? 
No need to worry- our ESS Service Department can help!


Getting help is as easy as 1-2-3!

1- Send It:
Ship your instrument to ESS using the ESS
 "Speed-Up" Repair form to describe your problem. 

2- Inspect It:
Our technicians will thoroughly inspect your instrument & fax you a repair quote with what needs to be repaired. Just sign & fax back the form to get it repaired. 

3-Ship It:
After it has been repaired, ESS will ship your instrument back to you with Federal Express. 




Contact our Service Department today to see how they can help you!



Monday, January 25, 2016

Helpful Hints and Information: Part 1-Helpful Hints and Most Common Damage.

Helpful Hints



1- Always wear gloves when handling/reprocessing scopes.

2- Leak test after every procedure. This is the single most important preventative measure in avoiding fluid invasion, which causes 8-% of all image problems and costly repairs.
You can refer here to our previous post about the importance of Leak Testing.

3- Rinse off solutions well. Solution build-up can cause external damage. 



Most Common Damage



1- Angle Section:
 Pinholes, cuts, tears.

2- Insertion Tube:
Pinches & stretching. 

3- Fluid Invasion:
Internal corrosion as well as breakdown
of epoxies and sealants.

If you find you have any damage to your 
equipment, don't hesitate to 
contact the ESS Service Department!




Friday, January 22, 2016

Pelican Endoscopy. Removal of foreign bodies.


This is an old video that we used to show at conferences.
It shows fishing tackle being retrieved with the scope. You can also see live worms moving around inside of the pelican's stomach. 
This video was recorded with a VCR, 
an old Olympus fiber-optic endoscope,
 and one of our older ESS Endoscopy Cameras. 

Thursday, January 21, 2016

FAEP's 53rd Annual Ocala Equine Conference

Endoscopy Support Services will be at 
FAEP's 53rd Annual Ocala Equine Conferece
this weekend!
Make sure you come by to see what we have to offer!


Won't be at the conference?
Not a problem!
You can always see the products we
 offer at our online store

Overground Equine Laryngoscope Video Sample.


Wednesday, January 20, 2016

NAVC 2016

It's the last day of NAVC 2016!
It's not too late to stop by Booth 2200 to see which piece of Endoscopy equipment is the perfect fit for you!



Can't make it to NAVC?
Don't worry!
You can always check out everything we have to
 offer at our online store

Displaced Epiglottis


Equine Displaced Epiglottis 


Tuesday, January 19, 2016

NAVC 2016

If you're still at NAVC 2016, make sure you stop by Booth #2200 to say "Hi" to our team and to check out all the awesome products we have to offer!

Jim and Jimmy demonstrating some of our products. 

Swing by to say "Hi" to Jimmy (L) and Bob (R)!


PENTAX Reprocessing step-by-step

Brief Instructions for Manual Reprocessing
 from our friends at PENTAX.
(Please note: These instructions apply only for standard GI Endoscopes. For all other products, please refer to the instructions for use. Please see the instructions for use for your endoscope regarding which components may be brushed cleaned according to model)





Wipe insertion tube with a clean, lint-free cloth saturated with
 detergent solution immediately after examination. 




Alternately flush detergent solution and air through the suction channel.

Set the lever on the water bottle to "drain" and insufflate air alternately into air and water channel.

Clean any other channels (if present) with detergent solution. 



Disconnect the endoscope from the processor/light source and suction pump.

Attach the soaking cap on power supply connector. 
(For specialized devices, please use appropriate soaking cap according to your instructions.)



Remove all of the valves, the distal end cap (if present) and any further
 detachable components and submerge them in the detergent solution. 

Perform all further steps regarding reprocessing for these
 components according to your instructions. 



Perform Leakage Test 1- The Dry Test.

During the dry test move the angulation control knobs gently and
 rotate the ocular (if present) to see if the pressure drops. 

(If the pressure drops, discontinue Leakage Test 1, disinfect the 
endoscope externally, and contact ESS Service Department. )



Perform Leakage Test II- The Wet Test.

Submerge endoscope entirely in fluid; move the angulation 
control knobs and rotate the ocular (if present)

(If bubbles rise, discontinue Leakage Test II and

Always disconnect Leak Tester from scope above the fluid surface. 



Brush clean all of the channels that may be cleaned with brushes using the appropriate brush under fluid surface, following your instructions. 



Start brush cleaning with the power supply connector.



Brush clean valve cylinder(s) and any other openings. 



Finally, brush clean the channels - starting at the control body and moving towards the distal ends. 

If there are cleaning adapters, connect them for filling the channels with cleaning solution. 

Remove adapter at the beginning of the exposure time. 



Remove endoscope and any detached components from the cleaning solution. 

Use the cleaning adapter to rinse all of the channels and 
rinse the external surfaces with clean water. 



Submerge endoscope entirely in disinfectant solution.

Submerge any valves, the distal end cap (if present) and any further detachable components in the disinfectant solution. 



Attach the cleaning adapter for filling the channels
 with disinfectant solution. 

Remove adapter at the beginning of the exposure time. 

Follow the manufacturer's specifications in regard to
 disinfectant solution concentration and exposure time. 




Remove endoscope and any detached components from the disinfectant solution

Rinse all the channels and external surfaces with sterile-filtered or sterile water. 

Dry the channels, using medical grade compressed air is recommended. 



Remove protective caps and cleaning adapters (if present)

Store the endoscope preferably by hanging it in a dust-free, well ventilated cabinet. 

Store valves, distal end cap (if present) and other 
removable components separately from the endoscope. 



Attach valves, distal end cap (if present) and other removable components. 

Inspect valve o-rings and change if they do not seal,
 moisten o-rings sparingly with silicone oil if necessary.

Connect endoscope to the processor/light source.

Perform functionality check.



Note:

Review the Instructions for further details. 

Only use approved detergent and disinfectant solutions and follow the instructions regarding concentration, exposure time and temperature. 

Steps 12 and 14 may also be performed with washer-disinfectors for flexible endoscopes. Washer-disinfectors may not be exposed to temperatures above 60 degrees C. Pressure for leakage test may not exceed 0.2 bar. 

(PENTAX Medical and Endoscopy Support Services, Inc. accepts no liablity for damages arising from improper reprocessing. Country-specific regulations must be observed. )





MiSeal MiFusion Splenectomy


A bloodless Splenectomy done with the
MiSeal MiFusion device. 
To find out more about this product,
 check out our online store or contact us!

Saturday, January 16, 2016

NAVC 2016

Today is NAVC!

Make sure you stop by Booth 2200
 to see all that we have to offer!


Can't make it to NAVC 2016?
No problem!
You can always check out our products at our online store or contact us directly to see what we can do for you!

Thursday, January 14, 2016

Tips on Proper Endoscope Handling.

Here's what you can do to help prevent damage in your equipment. 
These tips will give you ways to minimize repair frequency and costs.



Leakage Testing
Performing a rigorous leak test-both dry and wet- before completing scope reprocessing is one of the most important ways you can protect your endoscope from being damaged.
(You can refer to our previous post here to learn more
 about Leakage Testing) 

Handling and Transport
Your endoscope's lenses, cover glasses, and the distal end can be damaged if subjected to a significant shock. Likewise, control bodies and insertion tubes can be damaged from impact or excess pressure being placed on them. 
Careful handling and transport will reduce the risk of damage. 
If endoscopes are transported by hand, the distal end should be held in one hand to prevent the possibility of accidental impact. Also, endoscopes should be placed with their knobs up and never stacked. 
When it's necessary to ship a PENTAX Medical Endoscope, the original case should be used. 

Examination Room Layout
Optimizing the arrangement of the examination room can help avoid damage. In particular, buckling of the insertion tube and umbilical cable can be avoided with a carefully considered arrangement of the examination table, monitor, light source/processor and proper coiling of the scope. 

Storage
The endoscopes should be stored fully extended either freely hung up or laid down in a cabinet designed to hold flexible endoscopes. This prevents deformation or kinking damage and also allows the scope to drain.
(Check out the storage selection on our online store to see which one is the right fit for you!)

Accessories
Forceps, brushes, adapter, water bottles, o-rings, and all valves should be regularly examined for imperfections. Damaged equipment may scratch or perforate the endoscope's channels/ports.

Lubricants
Lubricants containing paraffin or Vaseline are unsuitable for PENTAX endoscopes. Lubricants of this type attack the surfaces of the tubing or the bending rubber. You can avoid deposits by carefully removing lubricant residues prior to disinfection or cleaning. 



If you have any questions about these tips, 
or want to know more, 

Throwback Thursday!

Throwback to past NAVC Conferences!

Make sure to stop by Booth 2200 at
 NAVC 2016 this week to see all that
 we have to offer!

Rich at our booth in 2015

Jimmy demonstrating our All-In-One Video Endoscopy System

Our booth at NAVC 2007

NAVC 2009


Can't make it to the show?
You can always check out our products at
 our online store or contact us directly!



Wednesday, January 13, 2016

Endoscopic removal of a Eucerin tube from a canine patient.


In this video, we removed a pocket sized tube 
of lotion from a 15 lb dog using 
the Ratigator Grasper 
and the Olympus Endoscope System. 

For more information about these products, 
check out our online store or contact us!

Tuesday, January 12, 2016

NAVC 2016

Are you going to NAVC next week?
Make sure to stop by Booth 2200 
to check out what we have to offer!